Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Insects ; 14(3)2023 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-36975958

RESUMEN

The mitochondrial marker, COII, was employed to assess the genetic structure and diversity of Anopheles funestus, a very important malaria vector in Africa that adapt and colonize different ecological niches in western Kenya. Mosquitoes were collected using mechanical aspirators in four areas (Bungoma, Port Victoria, Kombewa, and Migori) in western Kenya. Following morphological identification, PCR was used to confirm the species. The COII gene was amplified, sequenced, and analyzed to determine genetic diversity and population structure. A total of 126 (Port Victoria-38, Migori-38, Bungoma-22, and Kombewa-28) sequences of COII were used for population genetic analysis. Anopheles funestus had a high haplotype diversity (Hd = 0.97 to 0.98) but low nucleotide diversity (Π = 0.004 to 0.005). The neutrality test revealed negative Tajima's D and Fs values indicating an excess of low-frequency variation. This could be attributed to either population expansion or negative selection pressure across all the populations. No genetic or structural differentiation (Fst = -0.01) and a high level of gene flow (Gamma St, Nm = 17.99 to 35.22) were observed among the populations. Population expansion suggests the high adaptability of this species to various ecological requirements, hence sustaining its vectorial capacity and malaria transmission.

2.
Front Genet ; 13: 867906, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35656326

RESUMEN

Background: Malaria elimination and eradication efforts can be advanced by including transmission-blocking or reducing vaccines (TBVs) alongside existing interventions. Key transmission-blocking vaccine candidates, such as Pfs230 domain one and Pfs48/45 domain 3, should be genetically stable to avoid developing ineffective vaccines due to antigenic polymorphisms. We evaluated genetic polymorphism and temporal stability of Pfs230 domain one and Pfs48/45 domain three in Plasmodium falciparum parasites from western Kenya. Methods: Dry blood spots on filter paper were collected from febrile malaria patients reporting to community health facilities in endemic areas of Homa Bay and Kisumu Counties and an epidemic-prone area of Kisii County in 2018 and 2019. Plasmodium speciation was performed using eluted DNA and real-time PCR. Amplification of the target domains of the two Pfs genes was performed on P. falciparum positive samples. We sequenced Pfs230 domain one on 156 clinical isolates and Pfs48/45 domain three on 118 clinical isolates to infer the levels of genetic variability, signatures of selection, genetic diversity indices and perform other evolutionary analyses. Results: Pfs230 domain one had low nucleotide diversity (π = 0.15 × 10-2) with slight variation per study site. Six polymorphic sites with nonsynonymous mutations and eight haplotypes were discovered. I539T was a novel variant, whereas G605S was nearing fixation. Pfs48/45 domain three had a low π (0.063 × 10-2), high conservation index, and three segregating sites, resulting in nonsynonymous mutation and four haplotypes. Some loci of Pfs230 D1 were in positive or negative linkage disequilibrium, had negative or positive selection signatures, and others (1813, 1955) and (1813, 1983) had a history of recombination. Mutated loci pairs in Pfs48/45 domain three had negative linkage disequilibrium, and some had negative and positive Tajima's D values with no history of recombination events. Conclusion: The two transmission blocking vaccine candidates have low nucleotide diversity, a small number of zone-specific variants, high nucleotide conservation index, and high frequency of rare alleles. With the near fixation a polymorphic site and the proximity of mutated codons to antibody binding epitopes, it will be necessary to continue monitoring sequence modifications of these domains when designing TBVs that include Pfs230 and Pfs48/45 antigens.

3.
Front Immunol ; 13: 887213, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35603171

RESUMEN

Introduction: Current diagnostic tools for schistosomiasis are limited, and new tests are necessary to enhance disease diagnosis and surveillance. Identification of novel disease-specific biomarkers may facilitate the development of such tests. We evaluated a panel of biomarkers used in sepsis and parasitic diseases for their potential suitability in the diagnosis of schistosomiasis. Objective: The study evaluated the levels of systemic plasma biomarkers in relation to Schistosoma mansoni infection and parasite burden. Methods: Six biomarkers were measured in the plasma of children from schistosomiasis-endemic regions using ELISA. The concentration of soluble CD23 (sCD23) and lipopolysaccharide (LPS) was tested in 199 and 124 plasma samples, respectively, while interleukin-6 (IL-6), soluble triggering receptor expressed on myeloid (sTREM) cells, eotaxin-1, and fatty acid-binding protein (FABP) concentrations were tested in 30 plasma samples. Results: The concentration of IL-6, eotaxin-1, FABP, and LPS was similar between schistosome-infected and uninfected children. The schistosome-infected children had higher median levels of sTREM and sCD23 as compared to uninfected children, 119.0 (29.9-208.9) versus 10.7 (0.0-73.4) (p = 0.046) and 2,549.0 (1,899.0-3,356.0) vs. 2,035.0 (1,448.0-2,939.0) (p = 0.05), respectively. In addition, sTREM was positively correlated with egg density (p = 0.017). Conclusion: Our data show that active schistosomiasis per se is associated with elevated levels of sTREM and sCD23. sTREM has potential diagnostic and prognostic values. However, these biomarkers did not distinguish between children with low egg burden and uninfected children.


Asunto(s)
Interleucina-6 , Esquistosomiasis , Biomarcadores , Quimiocina CCL11 , Niño , Humanos , Kenia , Lipopolisacáridos , Receptor Activador Expresado en Células Mieloides 1
4.
Malar J ; 21(1): 129, 2022 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-35459178

RESUMEN

BACKGROUND: Accurate malaria diagnosis and appropriate treatment at local health facilities are critical to reducing morbidity and human reservoir of infectious gametocytes. The current study assessed the accuracy of malaria diagnosis and treatment practices in three health care facilities in rural western Kenya. METHODS: The accuracy of malaria detection and treatment recommended compliance was monitored in two public and one private hospital from November 2019 through March 2020. Blood smears from febrile patients were examined by hospital laboratory technicians and re-examined by an expert microscopists thereafter subjected to real-time polymerase chain reaction (RT-PCR) for quality assurance. In addition, blood smears from patients diagnosed with malaria rapid diagnostic tests (RDT) and presumptively treated with anti-malarial were re-examined by an expert microscopist. RESULTS: A total of 1131 febrile outpatients were assessed for slide positivity (936), RDT (126) and presumptive diagnosis (69). The overall positivity rate for Plasmodium falciparum was 28% (257/936). The odds of slide positivity was higher in public hospitals, 30% (186/624, OR:1.44, 95% CI = 1.05-1.98, p < 0.05) than the private hospital 23% (71/312, OR:0.69, 95% CI = 0.51-0.95, p < 0.05). Anti-malarial treatment was dispensed more at public hospitals (95.2%, 177/186) than the private hospital (78.9%, 56/71, p < 0.0001). Inappropriate anti-malarial treatment, i.e. artemether-lumefantrine given to blood smear negative patients was higher at public hospitals (14.6%, 64/438) than the private hospital (7.1%, 17/241) (p = 0.004). RDT was the most sensitive (73.8%, 95% CI = 39.5-57.4) and specific (89.2%, 95% CI = 78.5-95.2) followed by hospital microscopy (sensitivity 47.6%, 95% CI = 38.2-57.1) and specificity (86.7%, 95% CI = 80.8-91.0). Presumptive diagnosis had the lowest sensitivity (25.7%, 95% CI = 13.1-43.6) and specificity (75.0%, 95% CI = 50.6-90.4). RDT had the highest non-treatment of negatives [98.3% (57/58)] while hospital microscopy had the lowest [77.3% (116/150)]. Health facilities misdiagnosis was at 27.9% (77/276). PCR confirmed 5.2% (4/23) of the 77 misdiagnosed cases as false positive and 68.5% (37/54) as false negative. CONCLUSIONS: The disparity in malaria diagnosis at health facilities with many slide positives reported as negatives and high presumptive treatment of slide negative cases, necessitates augmenting microscopic with RDTs and calls for Ministry of Health strengthening supportive infrastructure to be in compliance with treatment guidelines of Test, Treat, and Track to improve malaria case management.


Asunto(s)
Antimaláricos , Malaria Falciparum , Malaria , Antimaláricos/uso terapéutico , Arteméter/uso terapéutico , Combinación Arteméter y Lumefantrina/uso terapéutico , Pruebas Diagnósticas de Rutina , Fiebre , Personal de Salud , Humanos , Kenia , Malaria/diagnóstico , Malaria/tratamiento farmacológico , Malaria Falciparum/diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa , Población Rural , Sensibilidad y Especificidad
5.
Malar J ; 20(1): 472, 2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34930283

RESUMEN

BACKGROUND: The gold standard for diagnosing Plasmodium falciparum infection is microscopic examination of Giemsa-stained peripheral blood smears. The effectiveness of this procedure for infection surveillance and malaria control may be limited by a relatively high parasitaemia detection threshold. Persons with microscopically undetectable infections may go untreated, contributing to ongoing transmission to mosquito vectors. The purpose of this study was to determine the magnitude and determinants of undiagnosed submicroscopic P. falciparum infections in a rural area of western Kenya. METHODS: A health facility-based survey was conducted, and 367 patients seeking treatment for symptoms consistent with uncomplicated malaria in Homa Bay County were enrolled. The frequency of submicroscopic P. falciparum infection was measured by comparing the prevalence of infection based on light microscopic inspection of thick blood smears versus real-time polymerase chain reaction (RT-PCR) targeting P. falciparum 18S rRNA gene. Long-lasting insecticidal net (LLIN) use, participation in nocturnal outdoor activities, and gender were considered as potential determinants of submicroscopic infections. RESULTS: Microscopic inspection of blood smears was positive for asexual P. falciparum parasites in 14.7% (54/367) of cases. All of these samples were confirmed by RT-PCR. 35.8% (112/313) of blood smear negative cases were positive by RT-PCR, i.e., submicroscopic infection, resulting in an overall prevalence by RT-PCR alone of 45.2% compared to 14.7% for blood smear alone. Females had a higher prevalence of submicroscopic infections (35.6% or 72 out of 202 individuals, 95% CI 28.9-42.3) compared to males (24.2%, 40 of 165 individuals, 95% CI 17.6-30.8). The risk of submicroscopic infections in LLIN users was about half that of non-LLIN users (OR = 0.59). There was no difference in the prevalence of submicroscopic infections of study participants who were active in nocturnal outdoor activities versus those who were not active (OR = 0.91). Patients who participated in nocturnal outdoor activities and use LLINs while indoors had a slightly higher risk of submicroscopic infection than those who did not use LLINs (OR = 1.48). CONCLUSION: Microscopic inspection of blood smears from persons with malaria symptoms for asexual stage P. falciparum should be supplemented by more sensitive diagnostic tests in order to reduce ongoing transmission of P. falciparum parasites to local mosquito vectors.


Asunto(s)
Malaria Falciparum/epidemiología , Microscopía/estadística & datos numéricos , Plasmodium falciparum/fisiología , Reacción en Cadena en Tiempo Real de la Polimerasa/estadística & datos numéricos , Población Rural/estadística & datos numéricos , Enfermedades no Diagnosticadas/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Kenia/epidemiología , Malaria Falciparum/parasitología , Masculino , Persona de Mediana Edad , Prevalencia , Enfermedades no Diagnosticadas/parasitología , Adulto Joven
6.
PLoS One ; 16(10): e0255321, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34634069

RESUMEN

BACKGROUND: An. funestus is a major Afrotropical vector of human malaria. This study sought to investigate the larval ecology, sporozoite infection rates and blood meal sources of An. funestus in western Kenya. METHODS: Larval surveys were carried out in Bungoma (Highland) and Kombewa (lowland) of western Kenya. Aquatic habitats were identified, characterized, georeferenced and carefully examined for mosquito larvae and predators. Indoor resting mosquitoes were sampled using pyrethrum spray catches. Adults and larvae were morphologically and molecularly identified to species. Sporozoite infections and blood meal sources were detected using real-time PCR and ELISA respectively. RESULTS: Of the 151 aquatic habitats assessed, 62/80 (78%) in Bungoma and 58/71(82%) in Kombewa were positive for mosquito larvae. Of the 3,193 larvae sampled, An. funestus larvae constitute 38% (1224/3193). Bungoma recorded a higher number of An. funestus larvae (85%, 95%, CI, 8.722-17.15) than Kombewa (15%, 95%, CI, 1.33-3.91). Molecular identification of larvae showed that 89% (n = 80) were An. funestus. Approximately 59%, 35% and 5% of An. funestus larvae co-existed with An. gambiae s.l, Culex spp and An. coustani in the same habitats respectively. Of 1,221 An. funestus s.l adults sampled, molecular identifications revealed that An. funestus constituted 87% (n = 201) and 88% (n = 179) in Bungoma and Kombewa, respectively. The Plasmodium falciparum sporozoite rate of An. funestus in Bungoma and Kombewa was 2% (3/174) and 1% (2/157), respectively, and the human blood index of An. funestus was 84% (48/57) and 89% (39/44) and for Bungoma and Kombewa, respectively. CONCLUSION: Man-made ponds had the highest abundance of An. funestus larvae. Multiple regression and principal component analyses identified the distance to the nearest house as the key environmental factor associated with the abundance of An. funestus larvae in aquatic habitats. This study serves as a guide for the control of An. funestus and other mosquito species to complement existing vector control strategies.


Asunto(s)
Anopheles/embriología , Larva/crecimiento & desarrollo , Malaria Falciparum/transmisión , Control de Mosquitos/métodos , Mosquitos Vectores/crecimiento & desarrollo , Mosquitos Vectores/parasitología , Animales , Anopheles/parasitología , Ecología , Humanos , Mosquiteros Tratados con Insecticida , Insecticidas/farmacología , Kenia , Larva/parasitología , Plasmodium falciparum/aislamiento & purificación
7.
F1000Res ; 8: 1518, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31656591

RESUMEN

Background: HIV-1 drug resistance (HIVDR) assays are critical components of HIV clinical management programs in the face of emerging drug resistance. However, the high costs associated with existing commercial HIVDR assays prohibit their routine usage in resource-limited settings. We present the performance characteristics of a modified commercial HIVDR testing assay. Methods: A total of 26 plasma samples were used to validate and assess the accuracy, precision, reproducibility and amplification sensitivity of a modified HIVDR assay by HIV genotyping. In addition, a cost comparison between the original and the modified assay was performed using the ingredient costing approach. Results: The performance characteristics of the modified assay were in agreement with the original assay. Accuracy, precision and reproducibility showed nucleotide sequence identity of 98.5% (confidence interval (CI), 97.9-99.1%), 98.67% (CI, 98.1-99.23) and 98.7% (CI, 98.1-99.3), respectively.  There was no difference in the type of mutations detected by the two assays (χ 2 = 2.36, p = 0.26). Precision and reproducibility showed significant mutation agreement between replicates (kappa = 0.79 and 0.78), respectively ( p < 0.05). The amplification sensitivity of the modified assay was 100% and 62.5% for viremia ≥1000 copies/ml and <1000 copies/ml respectively. Our assay modification translates to a 39.2% reduction in the cost of reagents. Conclusions: Our findings underscore the potential of modifying commercially available HIVDR testing assays into cost-effective, yet accurate assays for use in resource-limited settings.


Asunto(s)
Farmacorresistencia Viral/genética , Técnicas de Genotipaje/normas , VIH-1/efectos de los fármacos , VIH-1/genética , Infecciones por VIH , Humanos , Reacción en Cadena de la Polimerasa , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...